कॉल करें +91 70093 25774 [email protected]
TEJVAAN वारंटी रजिस्टर करें
TEJVAAN
वारंटी रजिस्टर करें कॉल करें +91 70093 25774
8 BAR
product-elite.png Drop the photo into /assets/img/ and it appears here
Premium series

TEJVAAN ELITE

Built for pressure and for the long run

TEJVAAN ELITE has a glass-lined inner tank, an 8 bar pressure rating and a 5 year tank warranty. It exists for the two conditions that finish ordinary geysers early: hard water, and the pressure found in high-rise flats or where a booster pump is fitted.

8 barPressure rating
2 yearsWarranty
5 yearsGlass-lined tank
15L · 25LCapacities
₹9,665 – ₹10,165 एमआरपी, सभी कर सहित
  • Made in India
  • 2 year warranty, registered online
  • Helpline 1800 270 8016
Why this model

For hard water, high-rise flats and booster pumps

A glass-lined tank, not bare steel

This is the difference that shows up on your bill rather than the spec sheet. In a hard-water area a steel tank needs descaling once or twice every season, at roughly ₹400 to ₹500 a time. A glass-lined tank typically goes two to three years between services. It slows scaling considerably — it does not stop it, and we are not going to pretend otherwise.

5 years on the tank

Five years total on the inner tank, not two plus an add-on. The tank is the part that ends a geyser's life, so covering it for five years is a statement about how it is built rather than a marketing number.

Rated to 8 bar, and fitted with a safety valve

Water pressure climbs with every floor, and a booster pump raises it further. A 4 bar tank on the twelfth floor is working near its limit; this one is not. An overpressure safety valve is fitted to relieve pressure before it can damage the tank.

The only model with an anode rod

A sacrificial magnesium rod that corrodes so the tank does not, and it is replaceable. The AQUA and AURA are not fitted with one. Combined with the glass lining and the glass-coated element, this is what the extra money actually buys.

Inside the unit

What you are actually paying for

Tap any part to see what it does and why it matters. Most geyser failures trace back to one of these six components.

8 bar IN OUT

1Outer body

Powder-coated steel outer shell. Its job is to protect the insulation and survive a decade in a damp bathroom without rusting through.

2High-density PUF insulation

The layer that decides your electricity bill. Thicker, denser foam holds heat overnight, so the element switches on less often. Thin insulation is the most common place a cheap geyser saves money.

3Glass-lined inner tank

Glass-coated rather than bare steel, and rated to 8 bar. The lining is what slows scaling: in hard water a steel tank needs descaling once or twice a season, where this typically goes two to three years. It reduces scaling considerably — it does not stop it. The 8 bar rating also means it copes with a booster pump or high-rise supply pressure.

4Glass-coated heating element

Coated rather than bare, for the same reason as the tank: scale finds it harder to take hold. Scale is what kills elements — it blankets the surface until heat cannot escape and the element cooks itself.

5Magnesium anode rod

A sacrificial rod that corrodes so the tank does not. It is meant to wear away, and it is replaceable — typically every one to two years depending on how hard your water is. The ELITE is the only model in the range fitted with one.

6Thermostat and thermal cut-out

Two independent devices, deliberately. The thermostat manages normal temperature; the cut-out is a separate safety that trips if the first one ever fails. One failure should never become a hazard.

7Overpressure safety valve

Fitted on the ELITE to relieve pressure before it can damage the tank — the situation that arises with a booster pump or unusually high supply pressure. A safety device, not a guarantee against every plumbing fault.

Running cost

What it costs to actually use

A geyser's price is paid once. Its electricity is paid every month for a decade. This works out roughly what yours would add to the bill, using your own tariff.

Indicative only. Real consumption depends on inlet water temperature, how hard your water is, thermostat setting and usage pattern.

per month, roughly
units per month

Assumes heating from about 20 °C to 60 °C. Insulation quality changes this materially — a well-insulated tank reheats less.

Specifications

Every variant

SKUCapacityMountingPressure WarrantyTank warrantyMRP
TJV-ELITE-15V 15L Vertical 8 bar 2 yr 5 yr ₹9,665
TJV-ELITE-25V 25L Vertical 8 bar 2 yr 5 yr ₹10,165

Common to every variant

Supply230 V AC, 50 Hz, single phase
InsulationHigh-density PUF
Inner tankGlass-lined
Heating elementGlass-coated
SafetyCapillary thermostat with independent thermal cut-out, pressure release valve, overpressure safety valve
Anode rodReplaceable magnesium anode rod fitted
MountingWall mounted, brackets supplied
Country of originIndia

Before you install

  • Installation by a qualified electrician, with correct earthing.
  • If your supply pressure exceeds 8 bar, fit a pressure reducing valve.
  • Never switch on before the tank is full.
  • Where water is hard, plan periodic descaling — it is maintenance, not a fault.
Read the warranty terms

Before you buy — can we service you?

Our geyser service network covers seven states in North India. Worth knowing now rather than after a fault.

वारंटी

Register in two minutes, claim without paperwork

Photograph your invoice once. We verify it within 48 hours and email you a warranty certificate as a PDF. After that, checking your cover needs nothing more than your mobile number.